IN701-KNX Series is the common platform for KNX
To integrate and connect KNX devices into any ASCII, BACnet or Modbus BMS systems. Or integrate any BACnet or Modbus Field bus and automation devices (like HVAC systems, counters, etc.) into a KNX system.
The type of application can now be configured in the Intesis Maps software (and there is no need any more to have 5 different hardware) simply by selecting the wanted template in Intesis Maps.
IN701KNX***0000
The “***” indicates the number of data points you need. The number can unfortunately not be changed afterwards with the Intesis Maps software.
|
Intesis MAPS template |
Application |
|
IN-MBS-KNX |
KNX to Modbus server |
|
IN-KNX-MBM |
Modbus client to KNX |
|
IN-BAC-KNX |
KNX to BACnet server |
|
IN-KNX-BAC |
BACnet client to KNX |
|
IN-ASCII-KNX |
KNX to ASCII server |
BACnet IP & MS/TP Client to KNX TP Application
Integrate any BACnet MS/TP or BACnet IP server device, with any KNX device or system. The aim of this integration is to make accessible BACnet objects data and resources from a KNX system, as if it was a part of the own KNX system and vice-versa.
FEATURES
UL Certified
BTL Certified
Support for KNX TP
Up to 3000 KNX communication objects
KNX standard Datapoint Types (DPT) available
Both BACnet IP and MS/TP supported
Possibility to scan for BACnet devices with BACnet Explorer
Easy integration & updates with Intesis MAPS
KNX TP to ASCII IP & Serial Server Application
Integrate any KNX device or installation, with an ASCII BMS or any ASCII IP or ASCII serial controller. The aim of this integration is to make accessible KNX communication objects and resources from an ASCII based control system or device, as if it was a part of the own ASCII system and vice-versa.
FEATURES
UL Certified
Support for both ASCII IP and ASCII Serial (232/485)
Automatically send a write request to the ASCII bus when its value changes
Use personalized ASCII strings
Support for KNX TP devices
Control up to 3000 KNX communication objects
Easy integration & updates with Intesis MAPS
KNX TP to BACnet IP & MS/TP Server Application
Integrate any KNX device or installation, with a BACnet BMS or any BACnet IP or BACnet MS/TP controller. The aim of this integration is to make accessible KNX communication objects and resources from a BACnet based control system or device, as if it was a part of the own BACnet system and vice-versa.
FEATURES
KNX TP to Modbus TCP & RTU Server Application
Integrate any KNX device or installation, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible KNX communication objects and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa.
FEATURES
Modbus TCP & RTU Master to KNX TP Application
Integrate any Modbus RTU or TCP server device, or both at the same time, with any KNX device or system. The aim of this integration is to make accessible Modbus registers data and resources from a KNX system, as if it was a part of the own KNX system and vice-versa.
FEATURES
All order codes:
IN701KNX1000000 Intesis protocol translator with KNX, Serial and IP support - 100 points
IN701KNX2500000 Intesis protocol translator with KNX, Serial and IP support - 250 points
IN701KNX6000000 Intesis protocol translator with KNX, Serial and IP support - 600 points
IN701KNX1K20000 Intesis protocol translator with KNX, Serial and IP support - 1200 points
IN701KNX3K00000 Intesis protocol translator with KNX, Serial and IP support - 3000 points
| Brand | : Intesis |
| Reference | : IN701KNX1000000 |
| Family | : KNX gateways |
| Color | : |
| Warranty | : 2 years |
| Return allowed | : No |
| Country of origin | : DE |
| Gross weight | : 356 g |
| Length | : 14 cm |
| Width | : 12.7 cm |
| Height | : 8.6 cm |