The most innovative and complete actuators on the POWER BLOCK market are renewed once again, now incorporating as a novelty Power Block io88, with the well-known powerful functions of the uBrick and Power Block series:
Power Block io88 features:
- 8 inputs (binary/analog)
- 8 configurable outputs
- Up to 8 binary outputs
- Up to 4 blinds
- Up to 2 Fan Coils
INPUTS
- Short/long press (suitable for conventional switches)
- Dimmer adjustment
- Shutters/Blinds
- KNX Scenes
- Sending value with different DPTs (1 bit, 1 byte - unsigned, percentage - 2 bytes float, 4 bytes)
- Multiple operations according to number of pulses
- Flashing function
- Pulse-triggered sequences with multiple telegram sends for different objects
- Manual activation of all entries with telegram sending on the front according to parameterized function
- Disable Function
- LEDs for input status Monitoring
BINARY OUTPUTS:
- Bus failure behavior
- Time counters (ascending/descending)
- Switching counters (ascendants/descendants)
- KNX scenes with delays between events
- 2 independent timers per output
- Alarms with priorities and ACK
- Disable feature
SHUTTER / BLIND OUTPUTS
- Bus Failure Behavior
- Lower/upper limits that can be modified by object
- KNX scenes with delay between events
- Presets with position/slats that can be modified by object
- Alarms with priorities and recognition
- Enable/Disable Feature
- Inverted Motion Object
- Control manual
- Precise positioning
FAN COIL with the most complete functions on the market:
- Bus failure/recovery behavior
- Multiple fan/valve restrictions (Max/Min/Eco/..)
- Fan delay when turning on, off, forced ventilation, etc.
- Thermostat monitoring
- Additional cyclic ventilation, even when HR is off
- Multiple ways of fan control: 3x1 bit, 1 byte percentage, 1 byte unsigned, value customization, etc.
- Alarms
- Etc.
Fan Coil Application Examples:
- Control of the fan from a simple KNX keypad or from any webserver, thermostat, etc... No need for complex logical functions to define special behaviors
- Operating restrictions by time slots (e.g. limiting fan speeds at night to avoid annoying noise)
- Delay the activation of the fan while the hot/cold water temperature in the pipes is reached, to avoid annoying drafts of unconditioned air.
- Timing of the MANUAL ventilation mode to return to AUTO mode after a defined time.
- Minimum dwell times at each speed to avoid sudden changes in ventilation.
- Switching off the fan while the valve is closed to reduce noise.
- Automatic valve flow to prevent limescale for long periods of non-use.
- Automatic switching on of the fan only to ventilate closed rooms and prevent the accumulation of bad odours.
- Etc...
ADVANCED FUNCTIONS available more than 100!! and independent channels:
- Thermostat
- Timers with Remaining Time bus sent
- Logical functions (Booleans, comparators, mathematics, filters, gates, DPT converters, etc.)
- KNX scenes with delays between events
- Setpoints
- Analog and digital alarms
- Overwriting User Parameters
- Saving of all variables with bus voltage failure
- Etc..